HIOKI 8861+8959+8958 MEMORY HiCORDER +DC/RMS UNIT+16ch SCANNER
SOLD OUT SOLD
rec90






SOLD ありがとうございました

Accesary :9327 Logic Probe*2,Poewr Code
Number of input Units:Max. 8 units
Number of channels:Max. 32 analog channels (max. 128 channels with scanner unit) + 16 logic channels (standard configuration)
Measurement ranges(20 div full-scale):
5mV to 20V/div, 12 ranges, (using the 8956), resolution : 1/100 of range
Max. allowable input:DC 400V (using the 8956)
Frequency characteristics:DC to 10MHz (using the 8956)
Power consumption:100 to 240 V AC (50/60 Hz) (280 VA max. printer not used)
12 V DC (use the DC POWER UNIT 9684 : option, factory installation only)
Dimensions, mass:330 mm (12.99 in) W × 250 mm (9.84 in) H × 284.5 mm (11.20 in) D, 10.5 kg (370.4 oz) (printer not installed)
Measurement functions:MEM (high-speed recording) REC (real-time recording) REC & MEM (realtime recording + high-speed recording) FFT (frequency analysis) Real-time Save (records directly to storage media)
Data storage media:PC Card Type II slot × 2, Hard disk drive (option) × 1
Display:10.4 inch TFT color LCD (SVGA, 800 × 600 dots)
External interfaces:GP-IB (PC card), USB2.0 (series A receptacle 3 ports), LAN (HTTP/FTP/ Send mail or other), Monitor output (15-pin D-sub, SVGA output)


DC/RMS DCUNIT 8959
Isolated BNC connector (input impedance 1 MΩ, input capacitance 30 pF), Max. rated voltage to earth: 370 V AC, 5 mV to 20 V/division, 12 ranges, full scale: 20 divisions, AC voltage for possible measurement/display using the memory function: 280 V rms, low-pass filter: 5/500/5k/100k Hz,DC amplitude: ±0.4% of full scale (with filter 5 Hz), zero position: ±0.1% of full scale (with filter 5 Hz, after zero adjustment),DC to 400 kHz ±3 dB, with AC coupling: 7 Hz to 400 kHz ±3 dB

16ch SCANNER UNIT 8958
Voltage input/Thermocouple input: screw-type terminal strip, recommended wire diameter *1, detachable terminal block (with cover) ,5m, 50m, 500m, 2 V/division, 4 ranges, full scale: 20 divisions, measurement range: ±100% of full scale, digital filter: 50/60/10 Hz, measurement resolution 1/1600 of measurement range (using 16-bit A/D conversion; installed in 8860 series),Voltage: ±0.2% of full scale, thermocouple (K, J, E, T, N): ±0.05% of full scale ±1°C, (R, S, B, W): ±0.05% of full scale ±2°C (400°C or more), ±0.05% of full scale ±3.5°C (less than 400°C), reference junction compensation accuracy: ±1°C (added to measurement accuracy with internal reference junction compensation),Voltage: ±0.2% of full scale, thermocouple (K, J, E, T, N): ±0.05% of full scale ±1°C, (R, S, B, W): ±0.05% of full scale ±2°C (400°C or more), ±0.05% of full scale ±3.5°C (less than 400°C), reference junction compensation accuracy: ±1°C (added to measurement accuracy with internal reference junction compensation)